Cryogenic ge detectors with interleaved electrodes: Design and modeling - IN2P3 - Institut national de physique nucléaire et de physique des particules
Article Dans Une Revue Journal of Low Temperature Physics Année : 2008

Cryogenic ge detectors with interleaved electrodes: Design and modeling

Résumé

Detectors fitted with interleaved collection electrodes offer a promising solution to the problem of surface event rejection in cryogenic Ge detectors for dark matter search. Detector design and modeling are discussed, based on computer simulations of the collection field and on pulse-shape analysis of the ionization signals. Test experiments with a prototype detector are presented in a companion paper by X. Defay et al. in this conference.

Dates et versions

in2p3-00825407 , version 1 (23-05-2013)

Identifiants

Citer

A. Broniatowski, X. Defay, A. Juillard, S. Marnieros, M. Chapellier, et al.. Cryogenic ge detectors with interleaved electrodes: Design and modeling. Journal of Low Temperature Physics, 2008, 151, pp.830-834. ⟨10.1007/s10909-008-9754-1⟩. ⟨in2p3-00825407⟩
25 Consultations
0 Téléchargements

Altmetric

Partager

More