Conference Papers Year : 2007

Calice Si-W EM Calorimeter: Preliminary Results of the Testbeams 2006

Abstract

The CALICE Si-W electromagnetic calorimeter has been tested with electron beams (1 to 6 GeV) at DESY in May 2006, as well as electrons (6 to 45 GeV) and hadrons (6 to 80 GeV) at CERN in August and October 2006. Several millions of events have been taken at different incident angles and three beam impact positions. The ECAL calibration is performed with muon beams and shows a good uniformity for nearly all channels. The large statistics available allows not only to characterise the ECAL physics performance, but also to identify subtle hardware effects.

Dates and versions

in2p3-00178533 , version 1 (11-10-2007)

Identifiers

  • HAL Id : in2p3-00178533 , version 1
  • ARXIV : 0709.2516

Cite

C. Carloganu, A.-M. Magnan. Calice Si-W EM Calorimeter: Preliminary Results of the Testbeams 2006. International Linear Collider Workshop 2007: LCWS2007 and ILC2007, May 2007, Hamburg (DESY), Germany. 8 p. ⟨in2p3-00178533⟩